The storage contract is subject to injection and withdrawal restrictions. The restrictions are set in accordance with the rules for Gas Storage Denmark (REGL) applicable from time to time.
Injection restrictions

 

75% of the injection capacity is available when the gas storage facility is filled up 95% or more. All injection capacity is available when the storage filling is below 95%.
 
The injection restrictions for storage year 2017-2018 are illustrated in the figure below.
 

2.     Withdrawal restrictions

 

85% of the withdrawal capacity is available when the storage filling is at or below 20%,  75% of the withdrawal capacity is available when the storage filling is at or below 15%,
50% of the withdrawal capacity is available when the storage filling is at or below 12.5%,
40% of the withdrawal capacity is available when the storage filling is at or below 10%,
30% of the withdrawal capacity is available when the storage filling is at or below 5%.
 